"A" Automatic Modular Extract Fans
- Modular axial fans
- Automatic shutters
- 12 models
- IPX4 - Splashproof
- 3 sizes for toilets, shower-rooms, bathrooms, utility rooms and kitchens
- For walls, ceilings or windows (with window kit)
- Standard, Pull Cord, Timer, Humidity Control and 2 Speed
- Exceeds Building Regulations requirements (including new Document F)
General
- axial fans to exhaust air and fumes directly outside or through short lengths of ducting
- silent, slow-moving, delayed action automatic shutters
- all fans with cords can be either cord operated or have cord removed and be operated via remote switch
- adjustable timer - 3-15 minutes
- dynamic humidistat with night time set back and anti-hunting device
- humidistat fans with anti-vibration gasket
- easy plasterboard ceiling istallation with (optional) Ceiling Ring
- window installation uses AWK window kits
- AWKDG double glazing kits available for 10 and 15cm sizes
- whisper quiet operation
- IPX4 - Splashproof - can safely be installed in Zones I and II
Back to top
Specification
- casings from shockproof and heat resistant plastics
- double insulated motors of shaded pole type mounted on self-lubricating, sealed ball bearings for long life
- motors incorporate thermal cut-out
- maximum ambient temperature - 40°C
Back to top
Compliance
- EN60335-2-80
- EC Low Voltage Directive 73/23-93/68
- EC Directive EMC89/336
- CE marked
Back to top
Range
- A10/4A, 12/5A - standard
- A10/4CA, 12/5CA, 15/6CA - pull cord or automatic
- A10/4AT, 12/5AT - overrun timer
- A10/4HCTA, - humidistat, cord, overrun timer, neon
- A15/6H2C - humidistat, 2 speed, cord, neon
SELV models available
Back to top
Wiring
Back to top
Typical specification
Supply and install an A15/6CA modular axial kitchen fan as supplied by Vectaire Ltd, Lincoln Road, Cressex Business Park, High Wycombe, Bucks, HP12 3RH. The fan is to be suitable for installation either in a ceiling, wall or window, and have the facility of either being used manually (with the cord) or be operated as a fully automatic fan with remote switching. Shutters should be of the silent, slow moving, delay action type. The fan should be made of shockproof and heat resistant plastic, contain a motor with sealed, self lubricating bearings and be protected with a thermal cut-out. The fan should be double insulated, and be suitable for installation into Zones I and II. Fan to comply with all current IEE, EC and Building Regulations requirements for installation into a kitchen and be BEAB Approved.
Back to top