- General
- Specification
- Compliance
- Range
- Installation
- Wiring
- Pressure
- Dimensions
- Data
- Accessories
- Typical specification
- Leaflets
- O&M Sheets
AMF100T High Pressure Duct Fan
- High pressure duct fan
- With timer
- IPX4 - Splashproof
- For toilets, shower-rooms, bathrooms and utility rooms
- For walls, ceilings or windows (with window kit)
- Exceeds Building Regulations requirements (including new Document F)
General
- high pressure duct fan to exhaust air and fumes through long lengths of rigid or flexible ducting
- hole diameter 4"/10cm
- integral backdraught shutter
- anti-vibration gasket
- for window installation use AWK10/4 or AWK10/4DG and remove backdraught shutter
- adjustable timer - 3-15 minutes
- dynamic humidistat with night time setback and anti-hunting device
- humidistat model with neon to show fan in manual operation
- easy plasterboard ceiling installation with (optional) Ceiling Ring
- easy wiring with quick fit terminal block
- whisper quiet operation
- IPX4 - Splashproof - can safely be installed in Zones I and II
Back to top
Specification
- casings from shockproof and heat resistant plastics
- double insulated motors of shaded pole type mounted on self-lubricating, sealed ball bearings for long life
- motors incorporate thermal cut-out
- maximum ambient temperature - 40°C
Back to top
Compliance
- IEC60335-2-80
- LVD2006/95/CE
- EMC2014/30/UE (European Directive
against radio interference and electromagnetic compatibility)
- CE Marked
Back to top
Typical specification
Supply and install a Vectaire AMF100T high pressure duct fan for toilets, shower-rooms, bathrooms and utility rooms as supplied by Vectaire Ltd, Lincoln Road, Cressex Business Park, High Wycombe, Bucks, HP12 3RH. This fan is to be suitable for installation either in a ceiling, wall or window (with the appropriate accessories). The fan should be complete with an integral timer adjustable from between three and fifteen minutes, have an integral back-draught shutter and an anti-vibration gasket. The fan casing should be made of shockproof and heat resistant plastics, contain a motor with sealed, self-lubricating ball bearings and be protected with a thermal cut-out. The fan should be double insulated, and be suitable for installation for Zones I and II. Fan to comply with all current IEE, EC and Building Regulations requirements for installation into a toilet, shower-room, bathroom or utility room.